Draft version of RIR
This draft RIR is merely for information purposes and is not legally binding at the time of this publication and their contents can still undergo important modifications until officially released.
Nr | Parameter2) | Description | Comments |
1 | Radiocommunication service | Fixed | - |
2 | Application | Point-to-Point | CCDP (Co-Channel Dual Polarization) ACCP (Adjacent Channel Co-Polarization) |
3 | Frequency band | A: 41.000 - 42.000 GHz B: 42.500 - 43.500 GHz | - |
4 | Channelling | 28 MHz / 56 MHz / 112 MHz | Channel centre frequencies according to ERC/REC/(01)04, recommends 2 (Annex 5) and recommends 4 (Annex 6, option A). |
5 | Modulation / Occupied bandwidth | Class: 4L (16-QAM or higher). ACM is allowed. OBW: 28 / 56 / 112 MHz. | Definition of spectral efficiency classes: refer to current version of EN 302 217-2 V3.3.1, clause 4.1.3. Limits for the spectrum masks: refer to current version of EN 302 217-2 V3.3.1, clause 4.2.3.2, Figure 7. Adaptive Coded Modulation (ACM) is allowed. OBW with Class 4L (16-QAM or higher): 28 MHz / 56 MHz with or without ACM. 112 MHz in particularly justified cases with or without ACM. |
6 | Direction / Separation | 1500 MHz | FDD |
7 | Transmit power / Power density | Max. 50 dBW e.i.r.p.. | The operational e.i.r.p. will be specified in the license / individual assignment. |
8 | Channel access and occupation rules | - | - |
9 | Authorisation regime | Switzerland: License required. Liechtenstein: Individual assignment required. | - |
10 | Additional essential requirements | - | - |
11 | Frequency planning assumptions | EN 302 217-2. RX input level = - 40 dBm. ATPC control range = min. 10 dB to max. 20 dB. | Conditions for the nominal RX input level: - Receiver input, point A in the system block diagram (EN 302 217-1), - RX input level tolerance: +1 to -10 dB, - ATPC set to min. TX output power in clear sky conditions (i.e. without rain fading). ===== ATPC power increases shall be triggered on the basis of propagation effects only. The ATPC system shall not remain at max. available power (EN 302 217-1, clause 3.1) for more than 15 consecutive minutes (ITU-R Rec. F.750). ===== Remote Transmit Power Control (RTPC) is considered to be an optional feature. ===== At first CCDP has to be used and then ACCP. ===== Limits for the spectrum masks: refer to current version of EN 302 217-2 V3.3.1, clause 4.2.3.2, Figure 7. ===== Allowed Reference Modes for ACM: - 28.0 MHz channelling with 16-QAM modulation, - 56.0 MHz channelling with 16-QAM modulation. ===== Min. link distance = 500 m. Site sharing radius = 150 m. ===== Class 3A, 3B, 3C antenna. Min. antenna gain = 38 dBi. Linear (horizontal or vertical) polarization. Antenna radiation pattern envelope (RPE) according to EN 302 217-4, Figure 29, 30, 31. OFCOM may impose tighter requirements than the minimum values given in EN 302 217-4 in order to maximize the use of the scarce spectrum resources (Class 4 antenna). |
12 | Planned changes | - | - |
13 | Reference | EN 302 217-2 / - / ECC/REC/(01)04. | Effective use of spectrum / ECC Decisions / ECC Recommendations. |
14 | Notification number | G/TBT/N/CHE/238 2019/9504/CH | - |
15 | Remarks | EN 301 489-4 | - |
Normative part: 1 to 11
Informative part: Nr 12 to 15
1) RIR for similar and/or other applications are available under: https://www.bakom.admin.ch/bakom/en/home/frequenzen-antennen/nationaler-frequenzzuweisungsplan/schnittstellen-anforderungen.html
2) For explanations and legal status, please refer to basis document 784.101.21 / RIR0000