Draft version of RIR
This draft RIR is merely for information purposes and is not legally binding at the time of this publication and their contents can still undergo important modifications until officially released.
Nr | Parameter2) | Description | Comments |
1 | Radiocommunication service | Fixed | - |
2 | Application | Point-to-Point | CCDP (Co-Channel Dual Polarized) ACCP (Adjacent Channel Co-Polarization) |
3 | Frequency band | A: 14.500 - 14.620 GHz B: 15.229 - 15.350 GHz | - |
4 | Channelling | 7 / 14 / 28 MHz | Channel centre frequencies according to CEPT/ERC/REC 12-07. |
5 | Modulation / Occupied bandwidth | Class: 2 and 4L (QPSK and 16-QAM or equivalent). ACM is allowed. OBW: 7 / 14 / 28 MHz. | Definition of spectral efficiency classes: refer to current version of EN 302 217-2 V3.2.2, clause 4.1.3. Adaptive Coded Modulation (ACM) is allowed. OBW with Class 2 (QPSK): 7 MHz without ACM. OBW with Class 2 (QPSK): 14 MHz in particularly justified cases and without ACM. OBW with Class 4L (16-QAM or equivalent): 7 / 14 MHz with or without ACM. OBW with Class 4L (16-QAM or equivalent): 28 MHz in particularly justified cases with or without ACM. |
6 | Direction / Separation | 728 MHz | FDD |
7 | Transmit power / Power density | Max. 55 dBW e.i.r.p. | The operational e.i.r.p. will be specified in the license / individual assignment. |
8 | Channel access and occupation rules | - | - |
9 | Authorisation regime | Switzerland: License required. Liechtenstein: Individual assignment required. | - |
10 | Additional essential requirements | - | - |
11 | Frequency planning assumptions | EN 302 217-2. Nominal RX input level = - 55 dBm. ATPC control range = min. 10 dB to max. 20 dB. | Conditions for the nominal RX input level: - Receiver input, point A in the system block diagram (EN 302 217-1), - RX input level tolerance: +1 to -10 dB, - ATPC set to min. TX output power in clear sky conditions (i.e. without rain fading). ===== ATPC power increases shall be triggered on the basis of propagation effects only. The ATPC system shall not remain at max. available power (current version of EN 302 217-1 V3.3.1, clause 3.1) for more than 15 consecutive minutes (ITU-R Rec. F.750). ===== Remote Transmit Power Control (RTPC) is considered to be an optional feature. ===== At first CCDP has to be used and then ACCP. ===== Limits for the spectrum masks: refer to current version of EN 302 217-2 V3.2.2, clause 4.2.3.2, Figure 7. ===== Allowed Reference Modes for ACM: - 7 / 14 / 28 MHz channelling with 16-QAM modulation. ===== Min. link distance = 10 km. Site sharing radius = 600 m. ===== Class 3 antenna. Min. antenna gain = 36 dBi. Linear (horizontal or vertical) polarization. Antenna radiation pattern envelope (RPE) according to current version of EN 302 217-4 V2.1.1, Figure 13. OFCOM may impose tighter requirements than the minimum values given in EN 302 217-4 in order to maximize the use of the scarce spectrum resources (Class 4 antenna). |
12 | Planned changes | - | - |
13 | Reference | EN 302 217-2 /-/ CEPT/ERC/REC 12-07. | Effective use of spectrum / ECC Decisions / ECC Recommendations. |
14 | Notification number | tbd. | - |
15 | Remarks | EN 301 489-4 | - |
Normative part: 1 to 11
Informative part: Nr 12 to 15
1) RIR for similar and/or other applications are available under: https://www.bakom.admin.ch/bakom/en/home/frequenzen-antennen/nationaler-frequenzzuweisungsplan/schnittstellen-anforderungen.html
2) For explanations and legal status, please refer to basis document 784.101.21 / RIR0000
© OFCOM (Swiss Federal Office of Communications)